Sales of telecommunication products

PE outer sheath
Suspended strength element (steel wire or steel rope)
Buffer tube
Hydrophobic gel
Optical fiberDestination
Optical cable is designed for aerial installation on overhead communication lines towers, power lines, lighting columns, between buildings; in cable ducts, in pipes, in blocks, in trays, in tunnels, in headers, on bridges and skyways, inside buildings.
Technical Characteristics
| Parameter | Value | |
| Number of optical fibers | 2-12 | 16-24 |
| Tensile strength (steel wire), kN | 2,6 | |
| Cable diameter, mm | 3,8 | 3,8 |
| Cable weight, kg/km | 44,7 | 45,8 |
| Tensile strength (steel wire), kN | 6,0 | |
| Cable diameter, mm | 4,4 | 4,4 |
| Cable weight, kg/km | 54,3 | 55,4 |
| Crushing force, kN/cm | 0,3 | |
| Operating temperature | -60°С…+70°С | |
| Installation temperature | -30°С…+50°С | |
| Transportation and storage temperature | -60°С…+70°С | |
| Minimum bending radius | Not less than 15 cable diameters | |
| Factory length, km | 3 | |
Technical characteristics of optical fiber
| Type of optical fiber | Corning SMF 28 Ultra | Corning SMF28e+BB |
| ITU-T recommendations | G.657A1 G.652D | G.657A1 G.652D |
| Deviation from the concentricity of the core, microns, not more | 0,5 | |
| Diameter of fiber sheath, microns | 125±0,7 | |
| Deviation from the roundness of the sheath, %, not more | 0,7 | |
| The diameter of the protective covering, microns | 242±5 | |
| Maximum attenuation at wavelength 1310 nm | 0,32 | 0,34 |
| Maximum attenuation at wavelength 1550 nm | 0,18 | 0,20 |
Full name example
Optical cable ОК8TS-8G.652D 6kN
The cable consists of a single tube core with freely laid fibers of G.652D Standard, the maximum tensile strength is 6kN.
Download the OK8TS cable specification in PDF
Download the OK8TS cable certificates and declarations in PDF