Optical cable is designed for installation in ground including swamps and shallow non-navigable river, in ducts, in pipes, in blocks, in trays, in tunnels, in headers, on bridges and skyways, between and inside buildings, for suspension on the supports of overhead communication lines towers, contact network and railways auto-blocking, power lines, lighting columns, power facilities, as well as with increased requirements for resistance to external electromagnetic influences.
Technical characteristics
Parameter | Value | ||||
Up to 6 | Up to 8 | Up to 12 | Up to 16 | Up to 24 | |
Tensile strength, kN | 8 | ||||
Cable diameter, mm | 10,7 | 10,7 | 10,7 | 10,7 | 10,9 |
Cable weight, kg/km | 111,0 | 110,9 | 110,8 | 110,6 | 113,5 |
Bending radius, mm | 160,5 | 160,5 | 160,5 | 160,5 | 163,5 |
Tensile strength, kN | 10 | ||||
Cable diameter, mm | 11,3 | 11,3 | 11,3 | 11,3 | 11,5 |
Cable weight, kg/km | 125,2 | 125,1 | 124,9 | 124,8 | 127,8 |
Bending radius, mm | 169,5 | 169,5 | 169,5 | 169,5 | 172,5 |
Tensile strength, kN | 12 | ||||
Cable diameter, mm | 11,9 | 11,9 | 11,9 | 11,9 | 12,1 |
Cable weight, kg/km | 144,5 | 144,4 | 144,2 | 144,1 | 147,3 |
Bending radius, mm | 178,5 | 178,5 | 178,5 | 178,5 | 181,5 |
Crushing force, kN/sm | 0,7 | ||||
Operating temperature | -50°С…+70°С | ||||
Installation temperature | -30°С…+50°С | ||||
Transportation and storage temperature | -60°С…+70°С | ||||
Minimum bending radius | Not less than 15 cable diameters | ||||
Factory length, km | 4 |
Technical characteristics of optical fiber
Type of optical fiber | Corning SMF 28 Ultra | Corning SMF28e+BB |
ITU-T recommendations | G.657A1 G.652D | G.657A1 G.652D |
Deviation from the concentricity of the core, microns, not more | 0,5 | |
Diameter of fiber sheath, microns | 125±0,7 | |
Deviation from the roundness of the sheath, %, not more | 0,7 | |
The diameter of the protective covering, microns | 242±5 | |
Maximum attenuation at wavelength 1310 nm | 0,32 | 0,34 |
Maximum attenuation at wavelength 1550 nm | 0,18 | 0,20 |
Full name example
Optical cable TOD-P-12Y (1x12) 10kN
The cable consists of a single tube with freely laid fibers. The free space is filled with a hydrophobic gel in the optical single tubes. The single tube is spirally covered with the dielectric rods armor. The free space is filled with a hydrophobic gel between rods. The armor is covered with HDPE sheath.