Sales of telecommunication products
Destination
Optical cable is designed for installation in ground including swamps and shallow non-navigable river, in ducts, in pipes, in blocks, in trays, in tunnels, in headers, on bridges and skyways, between and inside buildings
Technical characteristics
Parameter | Value | |||||
Number of optical fibers | Up to 16 | Up to 32 | Up to 48 | Up to 64 | Up to 72 | Up to 96 |
Crushing force, kN/sm | 0,4 | |||||
Tensile strength, kN | 7 | |||||
Cable diameter, mm | 12,4 | 12,6 | 13,0 | 13,2 | 14,2 | 14,2 |
Cable weight, kg/km | 231,0 | 239,6 | 252,0 | 260,7 | 295,6 | 295,6 |
Bending radius, mm | 186 | 189 | 195 | 198 | 312 | 213 |
Tensile strength, kN | 10 | |||||
Cable diameter, mm | 12,4 | 12,6 | 13,0 | 13,2 | 14,2 | 14,2 |
Cable weight, kg/km | 231,0 | 239,6 | 252,0 | 260,7 | 295,6 | 295,6 |
Bending radius, mm | 186 | 189 | 195 | 198 | 213 | 213 |
Crushing force, kN/sm | 1 | |||||
Tensile strength, kN | 40 | |||||
Cable diameter, mm | 17,6 | 18,0 | 18,6 | 19,0 | 20,0 | |
Cable weight, kg/km | 521,5 | 545,5 | 576,1 | 601,0 | 650,1 | |
Bending radius, mm | 264 | 270 | 279 | 285 | 300 | |
Crushing force, kN/sm | 0,3 | |||||
Operating temperature | -60°С…+70°С | |||||
Installation temperature | -30°С…+50°С | |||||
Transportation and storage temperature | -60°С…+70°С | |||||
Minimum bending radius | Not less than 15 cable diameters | |||||
Factory length, km | 4 |
Technical characteristics of optical fiber
Type of optical fiber | Corning SMF 28 Ultra | Corning SMF28e+BB |
ITU-T recommendations | G.657A1 G.652D | G.657A1 G.652D |
Deviation from the concentricity of the core, microns, not more | 0,5 | |
Diameter of fiber sheath, microns | 125±0,7 | |
Deviation from the roundness of the sheath, %, not more | 0,7 | |
The diameter of the protective covering, microns | 242±5 | |
Maximum attenuation at wavelength 1310 nm | 0,32 | 0,34 |
Maximum attenuation at wavelength 1550 nm | 0,18 | 0,20 |
Full name example
Optical cable DPS-P-48Y (6x8) 10kN
The cable consists of a loose tube core with a central strength element made of a dielectric around which optical loose tubes with freely laid fibers are twisted. The free space is filled with a hydrophobic gel in the optical loose tubes and in the core. The core is covered with intermediate PE sheath. The intermediate PE sheath is spirally covered with the steel wire armor. The free space is filled with a hydrophobic gel between wires. The armor is covered with HDPE sheath.
Download the DPS cable specification in PDF
Download the DPS cable certificates and declarations in PDF