Sales of telecommunication products
Destination
Optical cable is designed for suspension (with particularly high requirements for resistance to external electromagnetic effects) on overhead communication lines towers, railways contact network, power lines with a maximum electric field potential of up to 12 kV and between buildings.
Technical characteristics
Parameter | Value | ||||
Number of optical fibers | Up to 6 | Up to 8 | Up to 12 | Up to 16 | Up to 24 |
Tensile strength, kN | 4 | ||||
Cable diameter, mm | 6,2 | 6,3 | 6,5 | 6,7 | 7,0 |
Cable weight, kg/km | 72,9 | 73,7 | 75,5 | 77,4 | 80,2 |
Tensile strength, kN | 6 | ||||
Cable diameter, mm | 6,2 | 6,3 | 6,5 | 6,7 | 7,0 |
Cable weight, kg/km | 90,2 | 91,1 | 92,9 | 94,7 | 97,5 |
Crushing force, kN/sm | 0,3 | ||||
Operating temperature | -60°С…+70°С | ||||
Installation temperature | -30°С…+50°С | ||||
Transportation and storage temperature | -60°С…+70°С | ||||
Minimum bending radius | Не менее 15 диаметров кабеля | ||||
Factory length, km | 4 км |
Technical characteristics of optical fiber
Type of optical fiber | Corning SMF 28 Ultra | Corning SMF28e+BB |
ITU-T recommendations | G.657A1 G.652D | G.657A1 G.652D |
Deviation from the concentricity of the core, microns, not more | 0,5 | |
Diameter of fiber sheath, microns | 125±0,7 | |
Deviation from the roundness of the sheath, %, not more | 0,7 | |
The diameter of the protective covering, microns | 242±5 | |
Maximum attenuation at wavelength 1310 nm | 0,32 | 0,34 |
Maximum attenuation at wavelength 1550 nm | 0,18 | 0,20 |
Full name example
Optical cable TPOd-P-12Y (1x12) 6kN
The cable consists of a single tube core with freely laid fibers. Free space is filled with a hydrophobic gel in the single tube. A suspension element is a dielectric rod. MDPE sheath is laid on the core and on the suspension element.
Download the ТPOd cable specification in PDF
Download the ТPOd cable certificates and declarations in PDF